Description
Product Introduction
The TS205 Gas-Collecting Cylinder-Type Armored Level Transmitter is designed for continuous liquid-level measurement in demanding industrial environments, particularly applications involving high-temperature liquids, corrosive media and wastewater.
The transmitter consists of a stainless-steel gas-collecting cylinder, a stainless-steel capillary tube and a 2088 junction box. The sensing element and signal-processing circuit are housed inside the junction box, while the gas-collecting cylinder is immersed in the measured liquid to collect pressure signals.
During operation, the pressure generated by the liquid level acts on the gas trapped inside the collecting cylinder. This pressure signal is transmitted to the sensor through the stainless-steel capillary tube. By isolating the sensor from direct contact with the measured medium, this structural design helps protect the sensing components from high temperatures and corrosive substances.
With a full-metal armored construction, stainless-steel wetted components and IP68 protection, TS205 Gas-Collecting Cylinder-Type Armored Level Transmitter is suitable for liquid-level monitoring and control in wastewater treatment, chemical processing, industrial production and water management systems.
Key Features and Advantages
1. Indirect Pressure Measurement Design
The gas-collecting cylinder and capillary tube transmit liquid-level pressure to the sensor without requiring direct contact between the sensor and the measured medium. This design is suitable for challenging liquid measurement conditions.
2. Suitable for High-Temperature Media
The isolated sensing structure helps address measurement challenges associated with high-temperature liquids. The specified medium temperature range is -20°C to 100°C.
3. Corrosion-Resistant Stainless-Steel Construction
The level probe and capillary tube are manufactured from stainless steel, providing corrosion resistance for compatible industrial liquids and supporting reliable operation under different working conditions.
4. Full-Metal Armored Structure
The transmitter features a high-strength steel pipe structure that provides mechanical protection for the measurement assembly in demanding industrial environments.
5. Easy Installation
The submersible probe measurement design allows convenient installation in liquid tanks, sewage treatment facilities and other level measurement locations.
6. Optional Digital Display
A digital tube display is available as an option, allowing users to monitor measurement readings directly at the installation site.
7. Optional Filter Screen Assembly
For applications involving wastewater, sludge and other media containing suspended solids, a filter screen assembly can be added according to customer requirements.
Technical Specifications
|
Parameter |
Specification |
|---|---|
|
Model |
|
|
Product Type |
Gas-Collecting Cylinder-Type Armored Level Transmitter |
|
Measuring Principle |
Gas-collecting cylinder pressure measurement |
|
Measuring Range |
0–1 mH₂O to 0–20 mH₂O |
|
Standard Measuring Range |
0–20 mH₂O |
|
Accuracy |
±0.5% FS |
|
Power Supply |
18–36VDC |
|
Output Signal |
4–20mA |
|
Output with Display |
4–20mA (12–36VDC) |
|
Operating Temperature |
-20°C to 85°C |
|
Medium Temperature |
-20°C to 100°C |
|
Storage Temperature |
-40°C to 125°C |
|
Compensated Temperature |
0°C to 60°C |
|
Zero Thermal Drift |
±1.5% FS |
|
Sensitivity Thermal Drift |
±1.5% FS |
|
Mechanical Vibration |
20g (20–5000Hz) |
|
Shock Resistance |
10g (11ms) |
|
Insulation Resistance |
≥100MΩ / 250VDC |
|
Response Time |
≤1ms (rise to 90% FS) |
|
Long-Term Stability |
±0.2% FS / year |
|
Protection Rating |
IP68 |
|
Junction Box Material |
Low-copper aluminum alloy |
|
Level Probe Material |
Stainless steel |
|
Capillary Tube Material |
Stainless steel |
|
Media Compatibility |
Media compatible with 304 stainless steel |
|
Optional Configuration |
Digital display, filter screen assembly |
Technical parameters are subject to the selected measuring range and product configuration. Please confirm the required specifications before ordering.
Measuring Principle and Structural Design
The TS205 adopts a gas-collecting cylinder structure to achieve liquid-level measurement through pressure transmission.
Its main components include:
-
Stainless-Steel Gas-Collecting Cylinder: Immersed in the measured liquid to collect the pressure signal corresponding to the liquid level.
-
Stainless-Steel Capillary Tube: Transfers the pressure signal from the collecting cylinder to the sensing element.
-
2088 Junction Box: Houses the sensor and signal-processing circuitry for measurement and signal output.
This arrangement separates the sensing element from direct exposure to the measured liquid. It is particularly useful in applications where high temperature, corrosive properties or wastewater characteristics may affect conventional level measurement equipment.
Industrial Applications
The TS205 Gas-Collecting Cylinder-Type Armored Level Transmitter is suitable for liquid-level measurement and process control across various industrial sectors.
1. Environmental Protection and Sewage Treatment
Used for monitoring liquid levels in wastewater treatment facilities, sewage tanks and industrial wastewater systems. An optional filter screen assembly can be configured for wastewater containing suspended solids.
2. Chemical Industry
Suitable for liquid-level monitoring in chemical storage tanks and process vessels containing media compatible with 304 stainless steel, particularly where elevated medium temperatures require consideration.
3. Industrial Process Control
Provides continuous liquid-level signals for industrial automation and process monitoring systems, supporting equipment operation and liquid-level control.
4. Water Conservancy and Water Supply
Applicable to water management facilities, water storage tanks and variable-frequency water supply systems.
5. Sludge and Sedimentation Tanks
Suitable for level measurement in sedimentation tanks, sludge tanks and high-temperature waste liquid tanks, with optional filtration configurations depending on medium conditions.
Product Configuration and Customization
Different industrial applications require different measurement ranges, installation conditions and medium compatibility requirements.
Danrui Sensor provides configuration options to accommodate specific project requirements, including:
-
Measuring range selection from 1 mH₂O to 20 mH₂O
-
Optional digital tube display
-
Optional filter screen assembly for wastewater and sludge applications
-
Customized configurations according to installation conditions
-
Technical support for industrial liquid-level measurement applications
Before selecting a transmitter, customers should confirm the measuring range, medium temperature, liquid composition, installation depth and material compatibility to ensure suitable product selection.
Why Choose Danrui Sensor?
Danrui Sensor (Suzhou) Co., Ltd. specializes in the research, development and manufacturing of pressure sensors, differential pressure sensors and industrial measurement and control products.
Founded in 2011, the company has developed an integrated R&D and manufacturing operation supported by professional engineering teams, advanced production equipment and a data-driven quality management system.
Key Company Advantages
-
Industry Experience: Established in 2011, with extensive experience in industrial sensor measurement technology.
-
Professional Certifications: National High-Tech Enterprise, Private Technology Enterprise and Technology-Based SME.
-
Quality Management: Certified to ISO 9001:2015, supporting standardized manufacturing and quality control.
-
Environmental Management: Certified to ISO 14001:2015.
-
Occupational Health and Safety: Certified to ISO 45001:2018.
-
Patent Portfolio: Nearly 20 patents related to CE-TUV explosion-proof and flameproof technologies.
-
Digital Manufacturing: Intelligent production workshop supported by an MES system for manufacturing process traceability.
-
High-Precision Testing: Equipped with advanced testing equipment, with some core equipment offering measurement precision up to 0.005%.
-
Industry Recognition: Member of the China Instrument and Control Industry Association.
Digital Production and Quality Control
Danrui integrates advanced testing equipment with its Manufacturing Execution System (MES) to establish a traceable production and quality assurance process.
Each sensor is assigned a unique serial number (SN), connecting key manufacturing stages, including assembly, testing, aging and final inspection. This enables systematic production scheduling, standardized process management and product traceability.
Through continuous improvements in manufacturing technology and quality inspection, Danrui Sensor (Suzhou) Co., Ltd. provides reliable sensor products and measurement solutions for customers in petrochemicals, aerospace, shipbuilding, ordnance manufacturing and other industrial sectors.
Frequently Asked Questions
Q1: What is the TS205 Gas-Collecting Cylinder-Type Armored Level Transmitter used for?
It is designed for liquid-level measurement in industrial applications involving wastewater, sludge, chemical liquids and high-temperature media.
Q2: How does the gas-collecting cylinder measurement principle work?
The gas-collecting cylinder collects the pressure signal generated by the liquid level. The pressure is transmitted through a stainless-steel capillary tube to the sensor housed in the junction box, allowing measurement without direct sensor contact with the liquid.
Q3: What is the maximum medium temperature?
The specified medium temperature range is -20°C to 100°C. The transmitter's operating temperature range is -20°C to 85°C.
Q4: Can the TS205 measure wastewater and sludge?
Yes. It can be used in wastewater and sludge applications. A filter screen assembly can be added according to customer requirements.
Q5: Does the transmitter support a digital display?
Yes. A digital tube display is available as an optional configuration.
Q6: What is the protection rating?
The TS205 has an IP68 protection rating, making it suitable for submersible installation environments within its specified operating conditions.
Q7: What is the standard output signal?
The standard output is 4–20mA, with an 18–36VDC power supply. The display version supports 4–20mA with a 12–36VDC power supply.
Q8: What are the MOQ and delivery time?
The minimum order quantity is one piece. Standard products generally have a lead time of 7–20 days, excluding customized products.
Q9: Does Danrui accept OEM and ODM orders?
Yes. OEM and ODM services are available according to customer requirements.
Q10: What payment methods are accepted?
Available payment methods include T/T, L/C and D/P.
Ordering and Technical Support
For industrial users seeking reliable liquid-level measurement in wastewater treatment, chemical processing and high-temperature applications, TS205 Gas-Collecting Cylinder-Type Armored Level Transmitter offers an armored measurement structure with an isolated sensing design and flexible configuration options.
Contact Danrui Sensor (Suzhou) Co., Ltd. for detailed specifications, measuring range selection, optional accessories, OEM/ODM services and technical support.
Choose the appropriate TS205 configuration to meet your industrial liquid-level measurement and process control requirements.


Reviews
There are no reviews yet.